immersion probe Typesheet: TT6
  • measuring range: -30°C...180°C
  • response time: T05=6sec/ T09=18sec
  • outder diameter tube D: 6 mm
  • material (process-intrusive): V2A/V4A
  • connection wire (cable-jacket/wire): silicone/silicone 180°C, 2x0,34mm², CuSn
  • protection category: IP67 according to DIN EN 60529
Technical data
measuring range -30°C...180°C
response time T05=6sec/ T09=18sec *1
outder diameter tube D 6 mm
material (process-intrusive) V2A/V4A
connection wire (cable-jacket/wire) silicone/silicone 180°C, 2x0,34mm², CuSn *2
protection category IP67 according to DIN EN 60529
insulation resistance 500V DC testing voltage
ambient conditions
application area liquid and gaseous media
process pressure max 20bar *3
dew-point-resistance no

Type key configuration

Pos. Technical characteristics
Key
Expression
1 length of sleeve HL
A0
27mm
A1
35mm
A3
45mm
A4
60mm
A6
100mm
2 sensorelement-type
B0
Pt100, tolerance class B according to DIN EN 60751
B1
Pt100, tolerance class A according to DIN EN 60751
B2
Pt100, tolerance class AA according to DIN EN 60751
B3
Pt1000, tolerance class B according to DIN EN 60751
B4
Pt1000, tolerance class A according to DIN EN 60751
B5
Pt1000, tolerance class AA according to DIN EN 60751
B6
NTC 10K@25°C B25/85=3977 B±1%/R±1% *4
B7
NTC 5K@25°C B25/85=3977 B±1%/R±1% *4
B8
NTC 10K@25°C B25/85=3435 B±1%/R±1% *4
B9
NTC 10K@25°C B25/85=3977 B±1%/R±1%, valid from 50°C, <50°C is B2%/R2% *5
B10
NTC 2,2K@25°C B25/85=3552 B±1%/R±1% *4
B11
NTC 20K@25°C B25/85=3970 B±1%/R±1% *5
B12
KTY81-210
B13
KTY84-130
B14
KTY81-121
B15
KTY81-110
B16
NI100 tolerance class B, TK6180
B17
NI1000 tolerance class B, TK6180
3 cable length KL
C2
500mm-10+40 *7
C4
1000mm-50+100 *7
C5
1500mm-50+100 *7
C6
2000mm-50+100 *7
C7
2500mm-50+100 *7
C8
3000mm -50+100 *7
C9
4000mm -50+100 *7
C10
5000mm -100+200 *7
4 sensor connection
D0
wire end sleeves grey 0,75mm²
D3
wire ends tinned
5 bend-protection spring
E0
no
E1
bend-protection spring L=55mm, material 1.4310

Remarks

* 1 measured in water 70°C, 0,04m/sec
* 2 halogen-free
* 3 using a suiteable compression gland . The user has to check the combination of union and sensor. A shearing off of the sleeve material may not occur. The figure is based on values determined in the laboratory at room temperature and static pressure. Extended specification on request. The pressure strength does not refer to connection of cable/metal sleeve!
* 4 !!! CAUTION: This sensor element can only be loaded up to 125°C (short-term 150°C). The maximum temperature of the sensor is affected by this restriction!!!
* 5 NTC epoxy-coated, opterating temperature range -40...+150°C. typical drift of NTC-elements has to be considered, e.g.: storage in dry heat (t=155°C/1000h) 2% / storage in damp heat (T=40°C, rH 93%, 56 days) 1% / rapid temperature cycling (lowest temperature -55°C, upper temperature 155°C, number of cycles 100) 1% / endurance (Pmax 60mW /1000h) 3% / Long-term stability (T 70°C, 10.000h) 2%
* 7 stripping length AL=40mm +10-10

Do you have any questions about a product?

Direct contact:

+49 2721 / 6014 - 0
info(at)sontec.de

Things to know:

FAQs
Sontec catalogue